| /arch/mips/kernel/ |
| A D | cacheinfo.c | 60 int cpu1; in fill_cpumask_siblings() local 62 for_each_possible_cpu(cpu1) in fill_cpumask_siblings() 63 if (cpus_are_siblings(cpu, cpu1)) in fill_cpumask_siblings() 64 cpumask_set_cpu(cpu1, cpu_map); in fill_cpumask_siblings() 69 int cpu1; in fill_cpumask_cluster() local 72 for_each_possible_cpu(cpu1) in fill_cpumask_cluster() 73 if (cpu_cluster(&cpu_data[cpu1]) == cluster) in fill_cpumask_cluster() 74 cpumask_set_cpu(cpu1, cpu_map); in fill_cpumask_cluster()
|
| /arch/arm/boot/dts/samsung/ |
| A D | exynos5422-odroidhc1.dts | 62 <&cpu1 0 2>, 78 <&cpu1 3 8>, 88 cpu1_thermal: cpu1-thermal { 111 <&cpu1 0 2>, 122 <&cpu1 3 8>, 155 <&cpu1 0 2>, 166 <&cpu1 3 8>, 199 <&cpu1 0 2>, 210 <&cpu1 3 8>,
|
| A D | exynos5422-odroidxu3-lite.dts | 53 <&cpu1 3 7>, 64 <&cpu1 3 7>, 75 <&cpu1 3 7>, 86 <&cpu1 3 7>,
|
| A D | exynos5422-odroidxu3-common.dtsi | 113 <&cpu1 0 2>, 129 <&cpu1 3 8>, 139 cpu1_thermal: cpu1-thermal { 191 <&cpu1 0 2>, 202 <&cpu1 3 8>, 264 <&cpu1 0 2>, 275 <&cpu1 3 8>, 337 <&cpu1 0 2>, 348 <&cpu1 3 8>,
|
| A D | exynos4412-prime.dtsi | 33 cooling-device = <&cpu0 9 9>, <&cpu1 9 9>, 38 cooling-device = <&cpu0 15 15>, <&cpu1 15 15>,
|
| A D | exynos5420-arndale-octa.dts | 108 <&cpu1 0 2>, 124 <&cpu1 3 6>, 140 <&cpu1 6 11>, 179 <&cpu1 0 2>, 191 <&cpu1 3 6>, 203 <&cpu1 6 11>, 242 <&cpu1 0 2>, 254 <&cpu1 3 6>, 266 <&cpu1 6 11>, 305 <&cpu1 0 2>, [all …]
|
| /arch/arm64/boot/dts/mediatek/ |
| A D | mt8370.dtsi | 36 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 43 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 50 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 57 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 79 affinity = <&cpu0 &cpu1 &cpu2 &cpu3>;
|
| /arch/arm64/boot/dts/qcom/ |
| A D | sdm632.dtsi | 8 /delete-node/cpu1-thermal; 18 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 51 &cpu1 {
|
| A D | x1p42100.dtsi | 283 cpu1-0-top-thermal { 295 cpu1-0-btm-thermal { 307 cpu1-1-top-thermal { 319 cpu1-1-btm-thermal { 331 cpu1-2-top-thermal { 343 cpu1-2-btm-thermal { 355 cpu1-3-top-thermal { 367 cpu1-3-btm-thermal {
|
| /arch/x86/kernel/ |
| A D | smpboot.c | 322 int cpu1 = c->cpu_index, cpu2 = o->cpu_index; in topology_same_node() local 324 return (cpu_to_node(cpu1) == cpu_to_node(cpu2)); in topology_same_node() 330 int cpu1 = c->cpu_index, cpu2 = o->cpu_index; in topology_sane() local 335 cpu1, name, cpu2, cpu_to_node(cpu1), cpu_to_node(cpu2)); in topology_sane() 347 int cpu1 = c->cpu_index, cpu2 = o->cpu_index; in match_smt() local 384 int cpu1 = c->cpu_index, cpu2 = o->cpu_index; in match_l2c() local 387 if (per_cpu_l2c_id(cpu1) == BAD_APICID) in match_l2c() 391 if (per_cpu_l2c_id(cpu1) != per_cpu_l2c_id(cpu2)) in match_l2c() 433 int cpu1 = c->cpu_index, cpu2 = o->cpu_index; in match_llc() local 437 if (per_cpu_llc_id(cpu1) == BAD_APICID) in match_llc() [all …]
|
| /arch/arm64/boot/dts/amlogic/ |
| A D | meson-g12b.dtsi | 23 cpu = <&cpu1>; 56 cpu1: cpu@1 { label 123 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 132 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
| A D | meson-g12a.dtsi | 24 cpu1: cpu@1 { label 105 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 113 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
| A D | meson-gxm.dtsi | 19 cpu = <&cpu1>; 49 cpu1: cpu@1 { label 169 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 180 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
| /arch/arm64/boot/dts/ti/ |
| A D | k3-am62p-j722s-common-thermal.dtsi | 33 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 64 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 95 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
| A D | k3-am62a-thermal.dtsi | 33 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 64 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 95 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
| A D | k3-am62-thermal.dtsi | 33 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 64 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
| A D | k3-am642.dtsi | 24 cpu = <&cpu1>; 43 cpu1: cpu@1 { label
|
| /arch/arm64/boot/dts/st/ |
| A D | stm32mp233.dtsi | 10 cpu1: cpu@1 { label 23 interrupt-affinity = <&cpu0>, <&cpu1>; 27 cpu1_pd: power-domain-cpu1 {
|
| A D | stm32mp253.dtsi | 10 cpu1: cpu@1 { label 23 interrupt-affinity = <&cpu0>, <&cpu1>; 27 CPU_PD1: power-domain-cpu1 {
|
| /arch/arm64/boot/dts/realtek/ |
| A D | rtd1293.dtsi | 24 cpu1: cpu@1 { label 52 interrupt-affinity = <&cpu0>, <&cpu1>;
|
| A D | rtd1296.dtsi | 24 cpu1: cpu@1 { label 66 interrupt-affinity = <&cpu0>, <&cpu1>, <&cpu2>, <&cpu3>;
|
| A D | rtd1395.dtsi | 24 cpu1: cpu@1 { label 66 interrupt-affinity = <&cpu0>, <&cpu1>, <&cpu2>, <&cpu3>;
|
| A D | rtd1295.dtsi | 24 cpu1: cpu@1 { label 66 interrupt-affinity = <&cpu0>, <&cpu1>, <&cpu2>, <&cpu3>;
|
| /arch/arm64/boot/dts/exynos/ |
| A D | exynos5433-tmu.dtsi | 232 cooling-device = <&cpu0 1 2>, <&cpu1 1 2>, 238 cooling-device = <&cpu0 2 3>, <&cpu1 2 3>, 244 cooling-device = <&cpu0 3 4>, <&cpu1 3 4>, 250 cooling-device = <&cpu0 4 5>, <&cpu1 4 5>, 256 cooling-device = <&cpu0 5 9>, <&cpu1 5 9>,
|
| /arch/arm/boot/dts/allwinner/ |
| A D | sun8i-t113s.dtsi | 25 cpu1: cpu@1 { label 57 interrupt-affinity = <&cpu0>, <&cpu1>;
|