2 Power allocator governor tunables
8 The governor works optimally with the following two passive trip points:
10 1. "switch on" trip point: temperature above which the governor
15 "switch on" trip point. This the target temperature the governor
22 The power allocator governor implements a
104 thermal governor allows the configuration of two proportional term
115 value of `k_pu` will result in the governor granting very high power
168 the exact power that the governor requests. When the temperature
183 Cooling devices controlled by this governor must supply the additional
202 allocator governor to calculate how much power to give to each cooling
240 a given power set by the power allocator governor to a state that the
263 Limitations of the power allocator governor
266 The power allocator governor's PID controller works best if there is a
269 governor's `throttle()` function) repetitively, the governor response
271 governor, step-wise will also misbehave if you call its throttle()