Lines Matching refs:samples

49 This control is used to attenuate samples for left and right front PCM FX-bus
51 samples for 5.1 playback. The result samples are forwarded to the front DAC PCM
56 This control is used to attenuate samples for left and right surround PCM FX-bus
58 samples for 5.1 playback. The result samples are forwarded to the surround DAC PCM
63 This control is used to attenuate samples for center PCM FX-bus accumulator.
75 This control is used to attenuate samples for left and right PCM FX-bus
76 accumulators. ALSA uses accumulators 0 and 1 for left and right PCM samples for
77 stereo playback. The result samples are forwarded to the front DAC PCM slots
82 This control is used to attenuate samples for left and right PCM FX-bus
89 This control is used to attenuate samples for left and right MIDI FX-bus
90 accumulators. ALSA uses accumulators 4 and 5 for left and right MIDI samples.
91 The result samples are forwarded to the front DAC PCM slots of the AC97 codec.
95 These controls are used to attenuate samples for left and right MIDI FX-bus
102 This control is used to attenuate samples for left and right Mic input.
103 For Mic input is used AC97 codec. The result samples are forwarded to
109 This control is used to attenuate samples for left and right Mic input.
115 This control is used to attenuate samples from left and right IEC958 TTL
116 digital inputs (usually used by a CDROM drive). The result samples are
121 This control is used to attenuate samples from left and right IEC958 TTL
122 digital inputs (usually used by a CDROM drive). The result samples are
127 This control is used to attenuate samples from left and right IEC958 optical
128 digital input. The result samples are forwarded to the front DAC PCM slots
133 This control is used to attenuate samples from left and right IEC958 optical
134 digital inputs. The result samples are forwarded to the ADC capture FIFO
139 This control is used to attenuate samples from left and right I2S ADC
140 inputs (on the AudigyDrive). The result samples are forwarded to the front
145 This control is used to attenuate samples from left and right I2S ADC
146 inputs (on the AudigyDrive). The result samples are forwarded to the ADC
151 This control is used to attenuate samples from left and right I2S ADC
152 inputs from Philips ADC. The result samples are forwarded to the front
158 This control is used to attenuate samples from left and right I2S ADC
159 inputs Philips ADC. The result samples are forwarded to the ADC
164 This control is used to attenuate samples from left and right I2S ADC
165 inputs (on the AudigyDrive). The result samples are forwarded to the front
170 This control is used to attenuate samples from left and right I2S ADC
171 inputs (on the AudigyDrive). The result samples are forwarded to the ADC
177 This control is used to attenuate samples for left and right front speakers of
183 This control is used to attenuate samples for left and right surround speakers of
198 This control turns the tone control on or off. The samples for front, rear
204 When the tone control code is activated, the samples are always modified.
210 When the tone control code is activated, the samples are always modified.
215 This control is used to attenuate samples for front, surround, center and
220 If this switch is on, then the samples for the IEC958 (S/PDIF) digital
222 PCM samples are taken.
343 digital sound samples can be concurrently loaded
353 Interpolation looping of audio samples in cache connected to