/****************************************************************************** * Filename: aon_batmon.h * Revised: 2015-07-16 12:12:04 +0200 (Thu, 16 Jul 2015) * Revision: 44151 * * Description: Defines and prototypes for the AON Battery and Temperature * Monitor * * Copyright (c) 2015, Texas Instruments Incorporated * All rights reserved. * * Redistribution and use in source and binary forms, with or without * modification, are permitted provided that the following conditions are met: * * 1) Redistributions of source code must retain the above copyright notice, * this list of conditions and the following disclaimer. * * 2) Redistributions in binary form must reproduce the above copyright notice, * this list of conditions and the following disclaimer in the documentation * and/or other materials provided with the distribution. * * 3) Neither the name of the ORGANIZATION nor the names of its contributors may * be used to endorse or promote products derived from this software without * specific prior written permission. * * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" * AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE * ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE * LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE * POSSIBILITY OF SUCH DAMAGE. * ******************************************************************************/ //***************************************************************************** // //! \addtogroup aon_group //! @{ //! \addtogroup aonbatmon_api //! @{ // //***************************************************************************** #ifndef __AON_BATMON_H__ #define __AON_BATMON_H__ //***************************************************************************** // // If building with a C++ compiler, make all of the definitions in this header // have a C binding. // //***************************************************************************** #ifdef __cplusplus extern "C" { #endif #include #include #include #include #include #include //***************************************************************************** // // API Functions and prototypes // //***************************************************************************** //***************************************************************************** // //! \brief Enable the temperature and battery monitoring. //! //! This function will enable the measurements of the temperature and the //! battery voltage. //! //! To speed up the measurement of the levels the measurement can be enabled //! before configuring the battery and temperature settings. When all of the //! AON_BATMON registers are configured, the calculation of the voltage and //! temperature values can be enabled (the measurement will now take //! effect/propagate to other blocks). //! //! It is possible to enable both at the same time, after the AON_BATMON //! registers are configured, but then the first values will be ready at a //! later point compared to the scenario above. //! //! \note Temperature and battery voltage measurements are not done in //! parallel. The measurement cycle is controlled by a hardware Finite State //! Machine. First the temperature and then the battery voltage each taking //! one cycle to complete. However, if the comparator measuring the battery //! voltage detects a change on the reference value, a new measurement of the //! battery voltage only is performed immediately after. This has no impact on //! the cycle count. //! //! \return None // //***************************************************************************** __STATIC_INLINE void AONBatMonEnable(void) { // // Enable the measurements. // HWREG(AON_BATMON_BASE + AON_BATMON_O_CTL) = AON_BATMON_CTL_CALC_EN | AON_BATMON_CTL_MEAS_EN; } //***************************************************************************** // //! \brief Disable the temperature and battery monitoring. //! //! This function will disable the measurements of the temperature and the //! battery voltage. //! //! \return None // //***************************************************************************** __STATIC_INLINE void AONBatMonDisable(void) { // // Disable the measurements. // HWREG(AON_BATMON_BASE + AON_BATMON_O_CTL) = 0; } //***************************************************************************** // //! \brief Get the current temperature measurement as a signed value in Deg Celsius. //! //! This function returns an calibrated and rounded value in degree Celsius. //! The temperature measurements are updated every cycle. //! //! \note The temperature drifts slightly depending on the battery voltage. //! This function compensates for this drift and returns a calibrated temperature. //! //! \note Use the function AONBatMonNewTempMeasureReady() to test for a new measurement. //! //! \return Returns signed integer part of temperature in Deg C (-256 .. +255) //! //! \sa AONBatMonNewTempMeasureReady() // //***************************************************************************** int32_t AONBatMonTemperatureGetDegC( void ); //***************************************************************************** // //! \brief Get the battery monitor measurement. //! //! This function will return the current battery monitor measurement. //! The battery voltage measurements are updated every cycle. //! //! \note The returned value is NOT sign-extended! //! //! \note Use the function \ref AONBatMonNewBatteryMeasureReady() to test for //! a change in measurement. //! //! \return Returns the current battery monitor value of the battery voltage //! measurement in a format size <3.8> in units of volt. //! //! \sa AONBatMonNewBatteryMeasureReady() // //***************************************************************************** __STATIC_INLINE uint32_t AONBatMonBatteryVoltageGet(void) { uint32_t ui32CurrentBattery; ui32CurrentBattery = HWREG(AON_BATMON_BASE + AON_BATMON_O_BAT); // // Return the current battery voltage measurement. // return (ui32CurrentBattery >> AON_BATMON_BAT_FRAC_S); } //***************************************************************************** // //! \brief Check if battery monitor measurement has changed. //! //! This function checks if a new battery monitor value is available. If the //! measurement value has \b changed since last clear the function returns \c true. //! //! If the measurement has changed the function will automatically clear the //! status bit. //! //! \note It is always possible to read out the current value of the //! battery level using AONBatMonBatteryVoltageGet() but this function can be //! used to check if the measurement has changed. //! //! \return Returns \c true if the measurement value has changed and \c false //! otherwise. //! //! \sa AONBatMonNewTempMeasureReady(), AONBatMonBatteryVoltageGet() // //***************************************************************************** __STATIC_INLINE bool AONBatMonNewBatteryMeasureReady(void) { bool bStatus; // // Check the status bit. // bStatus = HWREG(AON_BATMON_BASE + AON_BATMON_O_BATUPD) & AON_BATMON_BATUPD_STAT ? true : false; // // Clear status bit if set. // if(bStatus) { HWREG(AON_BATMON_BASE + AON_BATMON_O_BATUPD) = 1; } // // Return status. // return (bStatus); } //***************************************************************************** // //! \brief Check if temperature monitor measurement has changed. //! //! This function checks if a new temperature value is available. If the //! measurement value has \b changed since last clear the function returns \c true. //! //! If the measurement has changed the function will automatically clear the //! status bit. //! //! \note It is always possible to read out the current value of the //! temperature using \ref AONBatMonTemperatureGetDegC() //! but this function can be used to check if the measurement has changed. //! //! \return Returns \c true if the measurement value has changed and \c false //! otherwise. //! //! \sa AONBatMonNewBatteryMeasureReady(), AONBatMonTemperatureGetDegC() // //***************************************************************************** __STATIC_INLINE bool AONBatMonNewTempMeasureReady(void) { bool bStatus; // // Check the status bit. // bStatus = HWREG(AON_BATMON_BASE + AON_BATMON_O_TEMPUPD) & AON_BATMON_TEMPUPD_STAT ? true : false; // // Clear status bit if set. // if(bStatus) { HWREG(AON_BATMON_BASE + AON_BATMON_O_TEMPUPD) = 1; } // // Return status. // return (bStatus); } //***************************************************************************** // // Mark the end of the C bindings section for C++ compilers. // //***************************************************************************** #ifdef __cplusplus } #endif #endif // __AON_BATMON_H__ //***************************************************************************** // //! Close the Doxygen group. //! @} //! @} // //*****************************************************************************