Home
last modified time | relevance | path

Searched refs:accuracy (Results 1 – 25 of 113) sorted by relevance

12345

/linux-6.3-rc2/Documentation/devicetree/bindings/clock/
A Dfixed-clock.yaml22 clock-accuracy:
23 description: accuracy of clock in ppb (parts per billion).
42 clock-accuracy = <100>;
/linux-6.3-rc2/arch/x86/math-emu/
A DREADME72 based upon getting good accuracy with reasonable speed.
237 The following table compares the emulator accuracy for the sqrt(),
243 accurate to 64 bits can result in a relative accuracy in cos() of
274 consequence, the accuracy of these functions for large arguments has
278 definition of accuracy has changed slightly from that used for the
313 accuracy in number of times per million, thus the second of these
314 columns shows that an accuracy of between 63.80 and 63.89 bits was
350 result of the given accuracy in bits (given in the left-most column)
359 results of relatively poor accuracy for these instructions when the
361 accuracy of the results were less than 62 bits, which occurs quite
[all …]
/linux-6.3-rc2/drivers/clk/
A Dclk-fixed-rate.c165 u32 accuracy = 0; in _of_fixed_clk_setup() local
171 of_property_read_u32(node, "clock-accuracy", &accuracy); in _of_fixed_clk_setup()
176 0, rate, accuracy); in _of_fixed_clk_setup()
/linux-6.3-rc2/Documentation/hwmon/
A Dshtc1.rst58 2. high or low accuracy. High accuracy is used by default and using it is
A Dtc74.rst18 and +- 2 degrees centigrade accuracy.
A Dsparx5-temp.rst24 The sensor has a range of -40°C to +125°C and an accuracy of +/-5°C.
A Dpc87360.rst74 readings more range or accuracy. Usually, users have to learn how it works,
81 slowest accuracy highest
94 * accuracy around 3000 RPM: 3000^2/clock
98 RPM as the lowest acceptable accuracy.
A Dadt7410.rst51 -55°C to +150°C. It has a high accuracy of +/-0.5°C and can be operated at a
65 a better accuracy (0.25°C instead of 0.50°C.)
A Dsht3x.rst38 2. high or low accuracy. High accuracy is used by default and using it is
A Dlan966x.rst25 its accuracy is +/- 5 degrees Celsius. The fan controller has a
A Dgl518sm.rst47 degrees, with a accuracy of +/-3 degrees.
54 give the readings more range or accuracy. Not all RPM values can
A Dmax6620.rst28 range or accuracy, the desired value can be set by a programmable register
A Demc2103.rst26 the readings more range or accuracy. Not all RPM values can accurately be
/linux-6.3-rc2/drivers/clk/at91/
A Dclk-main.c40 unsigned long accuracy; member
262 return osc->accuracy; in clk_main_rc_osc_recalc_accuracy()
295 u32 frequency, u32 accuracy) in at91_clk_register_main_rc_osc() argument
318 osc->accuracy = accuracy; in at91_clk_register_main_rc_osc()
A Dsckc.c53 unsigned long accuracy; member
183 return osc->accuracy; in clk_slow_rc_osc_recalc_accuracy()
228 unsigned long accuracy, in at91_clk_register_slow_rc_osc() argument
254 osc->accuracy = accuracy; in at91_clk_register_slow_rc_osc()
/linux-6.3-rc2/Documentation/ABI/testing/
A Dsysfs-bus-iio-adc-mt636012 Indicated MT6360 VBUS ADC with lower accuracy(+-75mA)
20 Indicated MT6360 VBUS ADC with higher accuracy(+-30mA)
A Dsysfs-bus-iio-light-tsl258320 It is used in the process of calibrating the device accuracy.
/linux-6.3-rc2/Documentation/devicetree/bindings/power/supply/
A Dmediatek,mt6370-charger.yaml50 VBUS voltage with lower accuracy (+-75mV) but higher measure
53 VBUS voltage with higher accuracy (+-30mV) but lower measure
/linux-6.3-rc2/drivers/iio/temperature/
A DKconfig23 high accuracy digital temperature measurement system.
68 tristate "MLX90632 contact-less infrared sensor with medical accuracy"
73 MLX90632 contact-less infrared sensor with medical accuracy
/linux-6.3-rc2/arch/arm/boot/dts/
A Dalphascale-asm9260.dtsi34 clock-accuracy = <30000>;
A Dpxa300-raumfeld-tuneable-clock.dtsi10 clock-accuracy = <100>;
/linux-6.3-rc2/drivers/hid/amd-sfh-hid/sfh1_1/
A Damd_sfh_interface.h131 u32 accuracy; member
/linux-6.3-rc2/Documentation/devicetree/bindings/mtd/
A Dlpc32xx-mlc.txt12 accuracy:)
/linux-6.3-rc2/Documentation/devicetree/bindings/mfd/
A Dmediatek,mt6370.yaml40 accuracy, higher measure range), VBUSDIV2 (higher accuracy, lower
/linux-6.3-rc2/Documentation/devicetree/bindings/iio/adc/
A Drichtek,rtq6056.yaml13 The RTQ6056 is a high accuracy current-sense monitor with I2C and SMBus

Completed in 38 milliseconds

12345