/linux-6.3-rc2/Documentation/devicetree/bindings/thermal/ |
A D | thermal-cooling-devices.yaml | 5 $id: http://devicetree.org/schemas/thermal/thermal-cooling-devices.yaml# 8 title: Thermal cooling device 25 This binding describes the cooling devices. 30 scaling (DVFS), and uses lower frequencies as cooling states. 34 Any cooling device has a range of cooling states (i.e. different levels of 45 "#cooling-cells": 48 the cooling-maps reference. The first cell is the minimum cooling state 49 and the second cell is the maximum cooling state requested. 59 // Example 1: Cpufreq cooling device on CPU0 75 #cooling-cells = <2>; [all …]
|
A D | thermal-idle.yaml | 8 title: Thermal idle cooling device 14 The thermal idle cooling device allows the system to passively 27 '#cooling-cells': 31 the cooling-maps reference. The first cell is the minimum cooling state 32 and the second cell is the maximum cooling state requested. 45 - '#cooling-cells' 59 // Example: Combining idle cooling device on big CPUs with cpufreq cooling device 73 #cooling-cells = <2>; /* min followed by max */ 76 #cooling-cells = <2>; 92 #cooling-cells = <2>; [all …]
|
A D | thermal-zones.yaml | 29 1. when passive cooling is activated (polling-delay-passive) 31 active cooling is activated. 135 cooling action is removed. 140 - active # enable active cooling e.g. fans 172 cooling-maps: 178 trip and the target cooling device state. 190 cooling-device: 194 and maximum cooling state specifiers for each cooling 197 use the minimum and maximum cooling state for that cooling 210 - cooling-device [all …]
|
/linux-6.3-rc2/arch/arm/boot/dts/ |
A D | exynos5422-odroidxu3-common.dtsi | 47 #cooling-cells = <2>; 48 cooling-levels = <0 130 170 230>; 94 cooling-maps { 97 cooling-device = <&fan0 0 1>; 101 cooling-device = <&fan0 1 2>; 105 cooling-device = <&fan0 2 3>; 114 cooling-device = <&cpu0 0 2>, 177 cooling-maps { 250 cooling-maps { 323 cooling-maps { [all …]
|
A D | exynos5422-odroidhc1.dts | 53 cooling-maps { 61 cooling-device = <&cpu0 0 2>, 77 cooling-device = <&cpu0 3 8>, 107 cooling-maps { 110 cooling-device = <&cpu0 0 2>, 121 cooling-device = <&cpu0 3 8>, 151 cooling-maps { 195 cooling-maps { 239 cooling-maps { 242 cooling-device = <&gpu 0 2>; [all …]
|
A D | rk3288-veyron-mickey.dts | 43 /delete-node/ cooling-maps; 83 cooling-maps { 90 cooling-device = <&cpu0 THERMAL_NO_LIMIT 4>, 97 cooling-device = <&gpu 1 1>; 142 cooling-device = <&gpu 2 2>; 149 /delete-node/ cooling-maps; 179 cooling-maps { 183 cooling-device = <&gpu THERMAL_NO_LIMIT 1>; 194 cooling-device = <&cpu0 4 4>, 203 cooling-device = <&gpu 2 2>; [all …]
|
A D | exynos5420-cpus.dtsi | 65 #cooling-cells = <2>; /* min followed by max */ 77 #cooling-cells = <2>; /* min followed by max */ 89 #cooling-cells = <2>; /* min followed by max */ 101 #cooling-cells = <2>; /* min followed by max */ 113 #cooling-cells = <2>; /* min followed by max */ 125 #cooling-cells = <2>; /* min followed by max */ 137 #cooling-cells = <2>; /* min followed by max */ 149 #cooling-cells = <2>; /* min followed by max */
|
A D | exynos5422-cpus.dtsi | 64 #cooling-cells = <2>; /* min followed by max */ 77 #cooling-cells = <2>; /* min followed by max */ 90 #cooling-cells = <2>; /* min followed by max */ 103 #cooling-cells = <2>; /* min followed by max */ 116 #cooling-cells = <2>; /* min followed by max */ 129 #cooling-cells = <2>; /* min followed by max */ 142 #cooling-cells = <2>; /* min followed by max */ 155 #cooling-cells = <2>; /* min followed by max */
|
A D | exynos4412-odroidu3.dts | 52 #cooling-cells = <2>; 53 cooling-levels = <0 102 170 230>; 70 cooling-maps { 73 cooling-device = <&cpu0 9 9>, <&cpu1 9 9>, 79 cooling-device = <&cpu0 15 15>, <&cpu1 15 15>, 85 cooling-device = <&fan0 0 1>;
|
/linux-6.3-rc2/Documentation/driver-api/thermal/ |
A D | sysfs-api.rst | 95 performing passive cooling. 232 the cooling device name. 242 cooling device. 271 thermal cooling device 282 and the cooling device can be in cooling state 0. 299 thermal cooling device 315 The cooling device pointer 323 contribute to the cooling of this zone unless all cooling 403 |---max_state: Maximum cooling state of the cooling device 404 |---cur_state: Current cooling state of the cooling device [all …]
|
A D | cpu-cooling-api.rst | 2 CPU cooling APIs How To 14 The generic cpu cooling(freq clipping) provides registration/unregistration APIs 15 to the caller. The binding of the cooling devices to the trip point is left for 16 the user. The registration APIs returns the cooling device pointer. 18 1. cpu cooling APIs 29 This interface function registers the cpufreq cooling device with the name 31 cooling devices. 41 This interface function registers the cpufreq cooling device with 44 instances of cpufreq cooling devices. 54 This interface function unregisters the "thermal-cpufreq-%x" cooling device.
|
/linux-6.3-rc2/arch/arm64/boot/dts/amlogic/ |
A D | meson-g12b.dtsi | 53 #cooling-cells = <2>; 63 #cooling-cells = <2>; 73 #cooling-cells = <2>; 83 #cooling-cells = <2>; 93 #cooling-cells = <2>; 103 #cooling-cells = <2>; 118 cooling-maps { 121 cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 130 cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
A D | meson-g12a.dtsi | 21 #cooling-cells = <2>; 30 #cooling-cells = <2>; 39 #cooling-cells = <2>; 48 #cooling-cells = <2>; 99 cooling-maps { 102 cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>, 110 cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
A D | meson-sm1-odroid-hc4.dts | 21 #cooling-cells = <2>; 22 cooling-min-state = <0>; 23 cooling-max-state = <3>; 24 cooling-levels = <0 120 170 220>; 87 cooling-maps { 90 cooling-device = <&fan0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
/linux-6.3-rc2/arch/arm64/boot/dts/exynos/ |
A D | exynos5433-tmu.dtsi | 54 cooling-maps { 58 cooling-device = <&cpu4 1 2>, <&cpu5 1 2>, 64 cooling-device = <&cpu4 2 3>, <&cpu5 2 3>, 70 cooling-device = <&cpu4 3 4>, <&cpu5 3 4>, 76 cooling-device = <&cpu4 4 5>, <&cpu5 4 5>, 82 cooling-device = <&cpu4 5 7>, <&cpu5 5 7>, 88 cooling-device = <&cpu4 7 9>, <&cpu5 7 9>, 94 cooling-device = <&cpu4 9 14>, <&cpu5 9 14>, 228 cooling-maps { 232 cooling-device = <&cpu0 1 2>, <&cpu1 1 2>, [all …]
|
/linux-6.3-rc2/drivers/gpu/drm/lima/ |
A D | lima_devfreq.c | 94 if (devfreq->cooling) { in lima_devfreq_fini() 95 devfreq_cooling_unregister(devfreq->cooling); in lima_devfreq_fini() 96 devfreq->cooling = NULL; in lima_devfreq_fini() 107 struct thermal_cooling_device *cooling; in lima_devfreq_init() local 169 cooling = of_devfreq_cooling_register(dev->of_node, devfreq); in lima_devfreq_init() 170 if (IS_ERR(cooling)) in lima_devfreq_init() 173 ldevfreq->cooling = cooling; in lima_devfreq_init()
|
/linux-6.3-rc2/Documentation/ABI/testing/ |
A D | sysfs-class-thermal | 78 for cooling device throttling control represents. 85 associated with; -1 means the cooling device is not 93 is relative to the rest of cooling devices in the thermal 94 zone. For example, if a cooling device has a weight double 95 than that of other, it's twice as effective in cooling the 106 different temperature threshold and its associated cooling 212 The maximum permissible cooling state of this cooling device. 218 The current cooling state of this cooling device. 221 - cur_state == 0 means no cooling 222 - cur_state == max_state means the maximum cooling. [all …]
|
/linux-6.3-rc2/drivers/gpu/drm/panfrost/ |
A D | panfrost_devfreq.c | 92 struct thermal_cooling_device *cooling; in panfrost_devfreq_init() local 163 cooling = devfreq_cooling_em_register(devfreq, NULL); in panfrost_devfreq_init() 164 if (IS_ERR(cooling)) in panfrost_devfreq_init() 167 pfdevfreq->cooling = cooling; in panfrost_devfreq_init() 176 if (pfdevfreq->cooling) { in panfrost_devfreq_fini() 177 devfreq_cooling_unregister(pfdevfreq->cooling); in panfrost_devfreq_fini() 178 pfdevfreq->cooling = NULL; in panfrost_devfreq_fini()
|
/linux-6.3-rc2/Documentation/devicetree/bindings/hwmon/ |
A D | pwm-fan.txt | 6 - cooling-levels : PWM duty cycle values in a range from 0 to 255 7 which correspond to thermal cooling states 25 #cooling-cells = <2>; 27 cooling-levels = <0 102 170 230>; 42 cooling-maps { 45 cooling-device = <&fan0 0 1>;
|
A D | aspeed-pwm-tacho.txt | 14 - #cooling-cells: should be 2. 34 For PWM port can be configured cooling-levels to create cooling device. 42 - cooling-levels: PWM duty cycle values in a range from 0 to 255 43 which correspond to thermal cooling states. 55 #cooling-cells = <2>; 65 cooling-levels = /bits/ 8 <125 151 177 203 229 255>;
|
/linux-6.3-rc2/arch/arm64/boot/dts/marvell/ |
A D | armada-8040-clearfog-gt-8k.dts | 38 #cooling-cells = <2>; 124 cooling-maps { 131 cooling-device = <&fan 4 5>; 160 cooling-maps { 163 cooling-device = <&fan 0 1>; 167 cooling-device = <&fan 1 2>; 171 cooling-device = <&fan 2 3>; 175 cooling-device = <&fan 3 4>; 179 cooling-device = <&fan 4 5>; 208 cooling-maps { [all …]
|
A D | armada-ap80x.dtsi | 334 cooling-maps { }; 356 cooling-maps { 359 cooling-device = <&cpu0 1 2>, 364 cooling-device = <&cpu0 3 3>, 389 cooling-maps { 392 cooling-device = <&cpu0 1 2>, 397 cooling-device = <&cpu0 3 3>, 422 cooling-maps { 425 cooling-device = <&cpu2 1 2>, 430 cooling-device = <&cpu2 3 3>, [all …]
|
/linux-6.3-rc2/arch/arm64/boot/dts/freescale/ |
A D | fsl-ls2080a.dtsi | 23 #cooling-cells = <2>; 33 #cooling-cells = <2>; 43 #cooling-cells = <2>; 53 #cooling-cells = <2>; 63 #cooling-cells = <2>; 73 #cooling-cells = <2>; 83 #cooling-cells = <2>; 93 #cooling-cells = <2>;
|
A D | fsl-ls2088a.dtsi | 23 #cooling-cells = <2>; 33 #cooling-cells = <2>; 43 #cooling-cells = <2>; 53 #cooling-cells = <2>; 63 #cooling-cells = <2>; 73 #cooling-cells = <2>; 83 #cooling-cells = <2>; 93 #cooling-cells = <2>;
|
/linux-6.3-rc2/Documentation/hwmon/ |
A D | mlxreg-fan.rst | 44 the system configuration and creates FAN/PWM hwmon objects and a cooling 49 one cooling device. It could be as many instances as programmable device 67 cur_state RW file for current cooling state of the cooling device 69 max_state RO file for maximum cooling state of the cooling device
|