Home
last modified time | relevance | path

Searched refs:measurement (Results 1 – 25 of 166) sorted by relevance

1234567

/linux-6.3-rc2/Documentation/devicetree/bindings/iio/adc/
A Dxlnx,zynqmp-ams.yaml28 AMS CTRL |0 |System PLLs voltage measurement, VCC_PSPLL. |Voltage
29 |1 |Battery voltage measurement, VCC_PSBATT. |Voltage
30 |2 |PL Internal voltage measurement, VCCINT. |Voltage
31 |3 |Block RAM voltage measurement, VCCBRAM. |Voltage
32 |4 |PL Aux voltage measurement, VCCAUX. |Voltage
33 |5 |Voltage measurement for six DDR I/O PLLs, VCC_PSDDR_PLL. |Voltage
34 |6 |VCC_PSINTFP_DDR voltage measurement. |Voltage
38 |9 |VCC PS LPD voltage measurement (supply1). |Voltage
39 |10 |VCC PS FPD voltage measurement (supply2). |Voltage
41 |12 |DDR I/O VCC voltage measurement. |Voltage
[all …]
/linux-6.3-rc2/Documentation/userspace-api/media/dvb/
A Dfrontend-stat-properties.rst64 measurement was not complete yet.
83 measurement was not complete yet.
114 measurement was not complete yet.
128 measurement was taken.
133 measurement interval.
142 measurement was not complete yet.
171 measurement was not complete yet.
185 measurement was taken.
190 measurement interval.
199 measurement was not complete yet.
[all …]
/linux-6.3-rc2/net/mac80211/
A Dspectmgmt.c214 skb_put(skb, 1 + sizeof(msr_report->u.action.u.measurement)); in ieee80211_send_refuse_measurement_request()
216 msr_report->u.action.u.measurement.action_code = in ieee80211_send_refuse_measurement_request()
218 msr_report->u.action.u.measurement.dialog_token = dialog_token; in ieee80211_send_refuse_measurement_request()
220 msr_report->u.action.u.measurement.element_id = WLAN_EID_MEASURE_REPORT; in ieee80211_send_refuse_measurement_request()
221 msr_report->u.action.u.measurement.length = in ieee80211_send_refuse_measurement_request()
224 memset(&msr_report->u.action.u.measurement.msr_elem, 0, in ieee80211_send_refuse_measurement_request()
226 msr_report->u.action.u.measurement.msr_elem.token = request_ie->token; in ieee80211_send_refuse_measurement_request()
227 msr_report->u.action.u.measurement.msr_elem.mode |= in ieee80211_send_refuse_measurement_request()
229 msr_report->u.action.u.measurement.msr_elem.type = request_ie->type; in ieee80211_send_refuse_measurement_request()
246 &mgmt->u.action.u.measurement.msr_elem, in ieee80211_process_measurement_req()
[all …]
/linux-6.3-rc2/drivers/s390/char/
A Duvdevice.c59 u8 *measurement, u8 *add_data, in uvio_copy_attest_result_to_user() argument
67 if (copy_to_user(user_buf_meas, measurement, uvio_attest->meas_len)) in uvio_copy_attest_result_to_user()
134 u8 *measurement = NULL; in uvio_attestation() local
154 measurement = kvzalloc(uvio_attest->meas_len, GFP_KERNEL); in uvio_attestation()
155 if (!arcb || !measurement) in uvio_attestation()
168 ret = uvio_build_uvcb_attest(uvcb_attest, arcb, measurement, add_data, uvio_attest); in uvio_attestation()
177 ret = uvio_copy_attest_result_to_user(uvcb_attest, uv_ioctl, measurement, add_data, in uvio_attestation()
181 kvfree(measurement); in uvio_attestation()
/linux-6.3-rc2/Documentation/hwmon/
A Dadm9240.rst52 microprocessor-based systems, providing measurement and limit comparison
59 measurement.
68 The measurement cycle
70 The adm9240 driver will take a measurement reading no faster than once
72 measurement update rate and will receive cached data from the most
73 recent measurement.
79 DS1780 measurement cycle is about once per second including fan speed.
81 LM81 measurement cycle is about once per 400ms including fan speed.
132 range, this will occur within a few measurement cycles.
144 Voltage (IN) measurement is internally scaled:
[all …]
A Dsht3x.rst33 1. blocking (pull the I2C clock line down while performing the measurement) or
47 2000 0.5 Hz periodic measurement
48 1000 1 Hz periodic measurement
49 500 2 Hz periodic measurement
50 250 4 Hz periodic measurement
51 100 10 Hz periodic measurement
54 In the periodic measure mode, the sensor automatically triggers a measurement
86 for periodic measurement. If the interval is not supported
A Dda9052.rst26 Channel 0 VDDOUT - measurement of the system voltage
27 Channel 1 ICH - internal battery charger current measurement
29 Channel 3 VBAT - measurement of the battery voltage
36 Channel 9 VBBAT - measurement of the backup battery voltage
A Dina238.rst47 power1_input Power measurement (uW)
51 curr1_input Current measurement (mA)
53 temp1_input Die temperature measurement (mC)
A Dmax34440.rst90 voltage measurement is enabled for a given channel. Voltage measurement is
91 enabled if currX_crit is set to 0; current measurement is enabled if the
92 attribute is set to a positive value. Power measurement is only enabled if
93 channel 1 (3) is configured for voltage measurement, and channel 2 (4) is
94 configured for current measurement.
/linux-6.3-rc2/Documentation/misc-devices/
A Dapds990x.rst20 functionality are highly connected. ALS measurement path must be running
23 ALS produces raw measurement values for two channels: Clear channel
35 selects suitable gain step. After each measurement, reliability of the results
36 is estimated and new measurement is triggered if necessary.
72 RW - measurement rate in Hz
75 RO - supported measurement rates
A Dbh1770glc.rst46 so that measurement produces about the expected lux value.
71 RW - measurement rate in Hz
74 RO - supported measurement rates
127 RO - Supported proximity measurement rates in Hz
/linux-6.3-rc2/Documentation/devicetree/bindings/iio/magnetometer/
A Dti,tmag5273.yaml19 on-axis and off-axis angle measurement topologies. The angle calculation is
32 ti,angle-measurement:
35 Enables angle measurement in the selected plane.
71 ti,angle-measurement = "x-z";
/linux-6.3-rc2/Documentation/devicetree/bindings/power/supply/
A Dstericsson,ab8500-battery.txt12 measurement, 'btemp' signal is used when NTC(negative temperature
21 for thermal measurement.
25 for thermal measurement.
/linux-6.3-rc2/security/integrity/ima/
A DKconfig33 bool "Enable carrying the IMA measurement list across a soft boot"
38 a TPM's quote after a soft boot, the IMA measurement list of the
41 Depending on the IMA policy, the measurement list can grow to
52 measurement list. If unsure, use the default 10.
66 Select the default IMA measurement template.
68 The original 'ima' measurement list template contains a
70 limited to 255 characters. The 'ima-ng' measurement list
92 Select the default hash algorithm used for the measurement
153 This option enables local measurement integrity appraisal.
155 attribute containing the file hash measurement. To protect
[all …]
/linux-6.3-rc2/Documentation/admin-guide/device-mapper/
A Ddm-ima.rst52 Then IMA ASCII measurement log has the following format:
103 The IMA measurement log has the following format for 'dm_table_load':
156 Then IMA ASCII measurement log will have the following entry:
173 The IMA measurement log has the following format for 'dm_device_resume':
197 then IMA ASCII measurement log will have an entry with:
211 The IMA measurement log has the following format for 'dm_device_remove':
235 then IMA ASCII measurement log will have the following entry:
252 The IMA measurement log has the following format for 'dm_table_clear':
269 then IMA ASCII measurement log will have an entry with:
302 then IMA ASCII measurement log will have an entry with:
[all …]
/linux-6.3-rc2/Documentation/devicetree/bindings/sound/
A Dcs43130.txt29 Boolean, define to enable headphone DC impedance measurement.
32 Boolean, define to enable headphone AC impedance measurement.
33 DC impedance must also be enabled for AC impedance measurement.
A Dda7219.txt51 - dlg,mic-det-thr : Impedance threshold for mic detection measurement (Ohms)
67 - dlg,btn-avg : Number of 8-bit readings for averaged button measurement
69 - dlg,adc-1bit-rpt : Repeat count for 1-bit button measurement
/linux-6.3-rc2/Documentation/userspace-api/media/v4l/
A Ddev-touch.rst30 A touch input may be determined by comparing the raw capacitance measurement to
31 a no-touch reference (or "baseline") measurement:
35 The reference measurement takes account of variations in the capacitance across
/linux-6.3-rc2/Documentation/virt/kvm/x86/
A Damd-memory-encryption.rst131 calculates a measurement of the memory contents. The measurement is a signature
151 The KVM_SEV_LAUNCH_MEASURE command is used to retrieve the measurement of the
154 measurement. Since the guest owner knows the initial contents of the guest at
155 boot, the measurement can be verified by comparing it to what the guest owner
158 If len is zero on entry, the measurement blob length is written to len and
168 __u64 uaddr; /* where to copy the measurement */
169 __u32 len; /* length of measurement blob */
172 For more details on the measurement verification flow, see SEV spec Section 6.4.
257 data after the measurement has been validated by the guest owner.
284 If len is zero on entry, the measurement blob length is written to len and
/linux-6.3-rc2/Documentation/ABI/testing/
A Dsysfs-bus-iio-chemical-sunrise-co229 - 'error_no_measurement': Cleared at first measurement
31 - 'error_measurement_timeout': Unable to complete measurement
/linux-6.3-rc2/Documentation/security/tpm/
A Dtpm_event_log.rst26 are accompanied by a measurement log. While not trusted on their own,
27 the measurement log contains a richer set of information than do the PCR
29 measurement log."
/linux-6.3-rc2/Documentation/driver-api/iio/
A Dintro.rst13 or temperature measurement. :doc:`Input <../input>` is, as its name suggests,
24 * inertial measurement units (IMUs)
/linux-6.3-rc2/drivers/greybus/
A Dinterface.c462 u32 measurement; in voltage_now_show() local
466 &measurement); in voltage_now_show()
472 return sprintf(buf, "%u\n", measurement); in voltage_now_show()
481 u32 measurement; in current_now_show() local
485 &measurement); in current_now_show()
491 return sprintf(buf, "%u\n", measurement); in current_now_show()
500 u32 measurement; in power_now_show() local
504 &measurement); in power_now_show()
510 return sprintf(buf, "%u\n", measurement); in power_now_show()
/linux-6.3-rc2/Documentation/security/
A DIMA-templates.rst26 which information should be included in the measurement list; a template
32 measurement entries. Defining a new template descriptor requires
41 mechanism) to generate a new measurement entry by using the template
48 (pointer to allocated data and data length) in the measurement entry structure.
103 To specify the template descriptor to be used to generate measurement entries,
/linux-6.3-rc2/Documentation/devicetree/bindings/iio/proximity/
A Dparallax-ping.yaml14 - ping-gpios is raised by the driver to start measurement
32 should initiate the measurement cycle. Afterwards the GPIO is switched

Completed in 39 milliseconds

1234567