/linux-6.3-rc2/Documentation/devicetree/bindings/iio/adc/ |
A D | xlnx,zynqmp-ams.yaml | 28 AMS CTRL |0 |System PLLs voltage measurement, VCC_PSPLL. |Voltage 29 |1 |Battery voltage measurement, VCC_PSBATT. |Voltage 30 |2 |PL Internal voltage measurement, VCCINT. |Voltage 31 |3 |Block RAM voltage measurement, VCCBRAM. |Voltage 32 |4 |PL Aux voltage measurement, VCCAUX. |Voltage 33 |5 |Voltage measurement for six DDR I/O PLLs, VCC_PSDDR_PLL. |Voltage 34 |6 |VCC_PSINTFP_DDR voltage measurement. |Voltage 38 |9 |VCC PS LPD voltage measurement (supply1). |Voltage 39 |10 |VCC PS FPD voltage measurement (supply2). |Voltage 41 |12 |DDR I/O VCC voltage measurement. |Voltage [all …]
|
/linux-6.3-rc2/Documentation/userspace-api/media/dvb/ |
A D | frontend-stat-properties.rst | 64 measurement was not complete yet. 83 measurement was not complete yet. 114 measurement was not complete yet. 128 measurement was taken. 133 measurement interval. 142 measurement was not complete yet. 171 measurement was not complete yet. 185 measurement was taken. 190 measurement interval. 199 measurement was not complete yet. [all …]
|
/linux-6.3-rc2/net/mac80211/ |
A D | spectmgmt.c | 214 skb_put(skb, 1 + sizeof(msr_report->u.action.u.measurement)); in ieee80211_send_refuse_measurement_request() 216 msr_report->u.action.u.measurement.action_code = in ieee80211_send_refuse_measurement_request() 218 msr_report->u.action.u.measurement.dialog_token = dialog_token; in ieee80211_send_refuse_measurement_request() 220 msr_report->u.action.u.measurement.element_id = WLAN_EID_MEASURE_REPORT; in ieee80211_send_refuse_measurement_request() 221 msr_report->u.action.u.measurement.length = in ieee80211_send_refuse_measurement_request() 224 memset(&msr_report->u.action.u.measurement.msr_elem, 0, in ieee80211_send_refuse_measurement_request() 226 msr_report->u.action.u.measurement.msr_elem.token = request_ie->token; in ieee80211_send_refuse_measurement_request() 227 msr_report->u.action.u.measurement.msr_elem.mode |= in ieee80211_send_refuse_measurement_request() 229 msr_report->u.action.u.measurement.msr_elem.type = request_ie->type; in ieee80211_send_refuse_measurement_request() 246 &mgmt->u.action.u.measurement.msr_elem, in ieee80211_process_measurement_req() [all …]
|
/linux-6.3-rc2/drivers/s390/char/ |
A D | uvdevice.c | 59 u8 *measurement, u8 *add_data, in uvio_copy_attest_result_to_user() argument 67 if (copy_to_user(user_buf_meas, measurement, uvio_attest->meas_len)) in uvio_copy_attest_result_to_user() 134 u8 *measurement = NULL; in uvio_attestation() local 154 measurement = kvzalloc(uvio_attest->meas_len, GFP_KERNEL); in uvio_attestation() 155 if (!arcb || !measurement) in uvio_attestation() 168 ret = uvio_build_uvcb_attest(uvcb_attest, arcb, measurement, add_data, uvio_attest); in uvio_attestation() 177 ret = uvio_copy_attest_result_to_user(uvcb_attest, uv_ioctl, measurement, add_data, in uvio_attestation() 181 kvfree(measurement); in uvio_attestation()
|
/linux-6.3-rc2/Documentation/hwmon/ |
A D | adm9240.rst | 52 microprocessor-based systems, providing measurement and limit comparison 59 measurement. 68 The measurement cycle 70 The adm9240 driver will take a measurement reading no faster than once 72 measurement update rate and will receive cached data from the most 73 recent measurement. 79 DS1780 measurement cycle is about once per second including fan speed. 81 LM81 measurement cycle is about once per 400ms including fan speed. 132 range, this will occur within a few measurement cycles. 144 Voltage (IN) measurement is internally scaled: [all …]
|
A D | sht3x.rst | 33 1. blocking (pull the I2C clock line down while performing the measurement) or 47 2000 0.5 Hz periodic measurement 48 1000 1 Hz periodic measurement 49 500 2 Hz periodic measurement 50 250 4 Hz periodic measurement 51 100 10 Hz periodic measurement 54 In the periodic measure mode, the sensor automatically triggers a measurement 86 for periodic measurement. If the interval is not supported
|
A D | da9052.rst | 26 Channel 0 VDDOUT - measurement of the system voltage 27 Channel 1 ICH - internal battery charger current measurement 29 Channel 3 VBAT - measurement of the battery voltage 36 Channel 9 VBBAT - measurement of the backup battery voltage
|
A D | ina238.rst | 47 power1_input Power measurement (uW) 51 curr1_input Current measurement (mA) 53 temp1_input Die temperature measurement (mC)
|
A D | max34440.rst | 90 voltage measurement is enabled for a given channel. Voltage measurement is 91 enabled if currX_crit is set to 0; current measurement is enabled if the 92 attribute is set to a positive value. Power measurement is only enabled if 93 channel 1 (3) is configured for voltage measurement, and channel 2 (4) is 94 configured for current measurement.
|
/linux-6.3-rc2/Documentation/misc-devices/ |
A D | apds990x.rst | 20 functionality are highly connected. ALS measurement path must be running 23 ALS produces raw measurement values for two channels: Clear channel 35 selects suitable gain step. After each measurement, reliability of the results 36 is estimated and new measurement is triggered if necessary. 72 RW - measurement rate in Hz 75 RO - supported measurement rates
|
A D | bh1770glc.rst | 46 so that measurement produces about the expected lux value. 71 RW - measurement rate in Hz 74 RO - supported measurement rates 127 RO - Supported proximity measurement rates in Hz
|
/linux-6.3-rc2/Documentation/devicetree/bindings/iio/magnetometer/ |
A D | ti,tmag5273.yaml | 19 on-axis and off-axis angle measurement topologies. The angle calculation is 32 ti,angle-measurement: 35 Enables angle measurement in the selected plane. 71 ti,angle-measurement = "x-z";
|
/linux-6.3-rc2/Documentation/devicetree/bindings/power/supply/ |
A D | stericsson,ab8500-battery.txt | 12 measurement, 'btemp' signal is used when NTC(negative temperature 21 for thermal measurement. 25 for thermal measurement.
|
/linux-6.3-rc2/security/integrity/ima/ |
A D | Kconfig | 33 bool "Enable carrying the IMA measurement list across a soft boot" 38 a TPM's quote after a soft boot, the IMA measurement list of the 41 Depending on the IMA policy, the measurement list can grow to 52 measurement list. If unsure, use the default 10. 66 Select the default IMA measurement template. 68 The original 'ima' measurement list template contains a 70 limited to 255 characters. The 'ima-ng' measurement list 92 Select the default hash algorithm used for the measurement 153 This option enables local measurement integrity appraisal. 155 attribute containing the file hash measurement. To protect [all …]
|
/linux-6.3-rc2/Documentation/admin-guide/device-mapper/ |
A D | dm-ima.rst | 52 Then IMA ASCII measurement log has the following format: 103 The IMA measurement log has the following format for 'dm_table_load': 156 Then IMA ASCII measurement log will have the following entry: 173 The IMA measurement log has the following format for 'dm_device_resume': 197 then IMA ASCII measurement log will have an entry with: 211 The IMA measurement log has the following format for 'dm_device_remove': 235 then IMA ASCII measurement log will have the following entry: 252 The IMA measurement log has the following format for 'dm_table_clear': 269 then IMA ASCII measurement log will have an entry with: 302 then IMA ASCII measurement log will have an entry with: [all …]
|
/linux-6.3-rc2/Documentation/devicetree/bindings/sound/ |
A D | cs43130.txt | 29 Boolean, define to enable headphone DC impedance measurement. 32 Boolean, define to enable headphone AC impedance measurement. 33 DC impedance must also be enabled for AC impedance measurement.
|
A D | da7219.txt | 51 - dlg,mic-det-thr : Impedance threshold for mic detection measurement (Ohms) 67 - dlg,btn-avg : Number of 8-bit readings for averaged button measurement 69 - dlg,adc-1bit-rpt : Repeat count for 1-bit button measurement
|
/linux-6.3-rc2/Documentation/userspace-api/media/v4l/ |
A D | dev-touch.rst | 30 A touch input may be determined by comparing the raw capacitance measurement to 31 a no-touch reference (or "baseline") measurement: 35 The reference measurement takes account of variations in the capacitance across
|
/linux-6.3-rc2/Documentation/virt/kvm/x86/ |
A D | amd-memory-encryption.rst | 131 calculates a measurement of the memory contents. The measurement is a signature 151 The KVM_SEV_LAUNCH_MEASURE command is used to retrieve the measurement of the 154 measurement. Since the guest owner knows the initial contents of the guest at 155 boot, the measurement can be verified by comparing it to what the guest owner 158 If len is zero on entry, the measurement blob length is written to len and 168 __u64 uaddr; /* where to copy the measurement */ 169 __u32 len; /* length of measurement blob */ 172 For more details on the measurement verification flow, see SEV spec Section 6.4. 257 data after the measurement has been validated by the guest owner. 284 If len is zero on entry, the measurement blob length is written to len and
|
/linux-6.3-rc2/Documentation/ABI/testing/ |
A D | sysfs-bus-iio-chemical-sunrise-co2 | 29 - 'error_no_measurement': Cleared at first measurement 31 - 'error_measurement_timeout': Unable to complete measurement
|
/linux-6.3-rc2/Documentation/security/tpm/ |
A D | tpm_event_log.rst | 26 are accompanied by a measurement log. While not trusted on their own, 27 the measurement log contains a richer set of information than do the PCR 29 measurement log."
|
/linux-6.3-rc2/Documentation/driver-api/iio/ |
A D | intro.rst | 13 or temperature measurement. :doc:`Input <../input>` is, as its name suggests, 24 * inertial measurement units (IMUs)
|
/linux-6.3-rc2/drivers/greybus/ |
A D | interface.c | 462 u32 measurement; in voltage_now_show() local 466 &measurement); in voltage_now_show() 472 return sprintf(buf, "%u\n", measurement); in voltage_now_show() 481 u32 measurement; in current_now_show() local 485 &measurement); in current_now_show() 491 return sprintf(buf, "%u\n", measurement); in current_now_show() 500 u32 measurement; in power_now_show() local 504 &measurement); in power_now_show() 510 return sprintf(buf, "%u\n", measurement); in power_now_show()
|
/linux-6.3-rc2/Documentation/security/ |
A D | IMA-templates.rst | 26 which information should be included in the measurement list; a template 32 measurement entries. Defining a new template descriptor requires 41 mechanism) to generate a new measurement entry by using the template 48 (pointer to allocated data and data length) in the measurement entry structure. 103 To specify the template descriptor to be used to generate measurement entries,
|
/linux-6.3-rc2/Documentation/devicetree/bindings/iio/proximity/ |
A D | parallax-ping.yaml | 14 - ping-gpios is raised by the driver to start measurement 32 should initiate the measurement cycle. Afterwards the GPIO is switched
|