1* Marvell PXA168 Ethernet Controller
2
3Required properties:
4- compatible: should be "marvell,pxa168-eth".
5- reg: address and length of the register set for the device.
6- interrupts: interrupt for the device.
7- clocks: pointer to the clock for the device.
8
9Optional properties:
10- port-id: Ethernet port number. Should be '0','1' or '2'.
11- #address-cells: must be 1 when using sub-nodes.
12- #size-cells: must be 0 when using sub-nodes.
13- phy-handle: see ethernet.txt file in the same directory.
14
15The MAC address will be determined using the optional properties
16defined in ethernet.txt.
17
18Sub-nodes:
19Each PHY can be represented as a sub-node. This is not mandatory.
20
21Sub-nodes required properties:
22- reg: the MDIO address of the PHY.
23
24Example:
25
26	eth0: ethernet@f7b90000 {
27		compatible = "marvell,pxa168-eth";
28		reg = <0xf7b90000 0x10000>;
29		clocks = <&chip CLKID_GETH0>;
30		interrupts = <GIC_SPI 24 IRQ_TYPE_LEVEL_HIGH>;
31		#address-cells = <1>;
32		#size-cells = <0>;
33		phy-handle = <&ethphy0>;
34
35		ethphy0: ethernet-phy@0 {
36			reg = <0>;
37		};
38	};
39