| /linux/drivers/md/dm-vdo/ |
| A D | admin-state.c | 70 .quiescent = true, 98 .quiescent = true, 123 .quiescent = true, 135 .quiescent = true, 331 if (code->quiescent) { in vdo_start_draining()
|
| A D | admin-state.h | 23 bool quiescent; member 136 return vdo_get_admin_state_code(state)->quiescent; in vdo_is_state_quiescent()
|
| A D | io-submitter.c | 348 VDO_ASSERT_LOG_ONLY(!code->quiescent, "I/O not allowed in state %s", code->name); in __submit_metadata_vio()
|
| A D | flush.c | 402 VDO_ASSERT_LOG_ONLY(!code->quiescent, "Flushing not allowed in state %s", in vdo_launch_flush()
|
| /linux/Documentation/RCU/Design/Memory-Ordering/ |
| A D | Tree-RCU-Memory-Ordering.rst | 408 quiescent states (or as described in a later section, had quiescent 410 non-idle CPUs report their own quiescent states, as shown in the 416 end of the grace period. Earlier quiescent states would push up the 418 that is waiting for additional quiescent states. However, ordering is 449 If the CPU does a context switch, a quiescent state will be noted by 453 Either way, the passage through a quiescent state will be noted in a 459 quiescent state, and invoke ``rcu_report_qs_rdp()``. If 472 guarantees that the first CPU's quiescent state happens before the 528 reporting on their behalf. This process is called “forcing quiescent 539 quiescent state will be driven up towards the root. As with [all …]
|
| /linux/Documentation/RCU/Design/Expedited-Grace-Periods/ |
| A D | Expedited-Grace-Periods.rst | 22 has not yet provided a quiescent state for the current expedited 29 a faster quiescent state where possible, and triggering a report 30 of that quiescent state. 31 As always for RCU, once everything has spent some time in a quiescent 53 in quiescent states. 61 If not, the handler can immediately report a quiescent state. 63 invocation will provide the needed quiescent-state report. 123 quiescent states. However, because the ``rcu_read_lock_sched()`` and 129 then ``rcu_exp_handler()`` reports the quiescent state. 134 quiescent state. Should the CPU go offline first, it will report the [all …]
|
| /linux/Documentation/RCU/Design/Data-Structures/ |
| A D | Data-Structures.rst | 39 such as quiescent states, dyntick-idle transitions, 50 has passed through a quiescent state. 104 the last CPU to report a quiescent state into a given ``rcu_node`` 112 there are in the system, at most 64 quiescent-state reports per grace 158 grace-period state, and maintains state used to force quiescent 161 quiescent-state information from the leaves to the root, and also 176 more-efficient propagation of quiescent states up the ``rcu_node`` 199 and maintains state used to force quiescent states when grace periods 436 structure's children still need to report quiescent states for the 905 forcing of quiescent states from ``call_rcu()`` and friends when [all …]
|
| /linux/Documentation/devicetree/bindings/regulator/ |
| A D | sprd,sc2731-regulator.yaml | 15 The SC2731 integrates low-voltage and low quiescent current DCDC/LDO.
|
| A D | maxim,max77802.yaml | 27 3 - Low Power which reduces the quiescent current down to only 1uA
|
| /linux/drivers/scsi/megaraid/ |
| A D | megaraid_ioctl.h | 284 uint32_t quiescent; member
|
| A D | mega_common.h | 156 uint8_t quiescent; member
|
| A D | megaraid_mm.c | 162 if (!adp->quiescent) { in mraid_mm_ioctl() 715 adp->quiescent = 0; in lld_ioctl() 929 adapter->quiescent = 1; in mraid_mm_register_adp()
|
| A D | megaraid_mbox.c | 1875 if (adapter->quiescent) { in megaraid_mbox_runpendq() 2152 if (!adapter->quiescent) { in megaraid_isr() 3648 adapter->quiescent++; in wait_till_fw_empty() 3703 adapter->quiescent--; in megaraid_mbox_mm_done()
|
| /linux/Documentation/networking/ |
| A D | ipvs-sysctl.rst | 175 persistent templates when the destination server is quiescent. 177 quiescent by setting its weight to 0 and it is desired that 180 connections are allowed to quiescent destination servers. 184 connection and the destination server is quiescent.
|
| /linux/tools/testing/selftests/sched_ext/ |
| A D | maximal.bpf.c | 141 .quiescent = (void *) maximal_quiescent,
|
| /linux/kernel/time/ |
| A D | Kconfig | 161 tracking to enter/exit RCU extended quiescent states. 178 userspace extended quiescent state and tickless cputime
|
| /linux/Documentation/admin-guide/cgroup-v1/ |
| A D | freezer-subsystem.rst | 16 quiescent state. Once the tasks are quiescent another task can
|
| /linux/drivers/scsi/ |
| A D | megaraid.c | 406 if (atomic_read(&adapter->quiescent) == 0) in megaraid_queue_lck() 1312 if(atomic_read(&adapter->quiescent) == 0) { in megaraid_isr_iomapped() 1392 if(atomic_read(&adapter->quiescent) == 0) { in megaraid_isr_memmapped() 2089 atomic_read(&adapter->quiescent)); in proc_show_config() 3773 atomic_set(&adapter->quiescent, 1); in mega_del_logdrv() 3800 atomic_set(&adapter->quiescent, 0); in mega_del_logdrv() 4078 if (atomic_read(&adapter->quiescent) == 0) in mega_internal_command() 4384 atomic_set(&adapter->quiescent, 0); in megaraid_probe_one()
|
| A D | megaraid.h | 854 atomic_t quiescent; /* a stage reached when delete logical member
|
| /linux/Documentation/RCU/Design/Requirements/ |
| A D | Requirements.rst | 854 *quiescent state* for each thread, that is, a state in which RCU knows 1440 to provide an RCU quiescent state. RCU also causes those CPUs' 1950 and also by reporting quiescent states explicitly when a CPU goes 1951 offline. This explicit reporting of quiescent states avoids any need 1952 for the force-quiescent-state loop (FQS) to report quiescent states for 1956 An offline CPU's quiescent state will be reported either: 1965 it does emit a warning if a quiescent state was not already reported 2046 quiescent state could result in line 4 being a use-after-free access, 2183 If the gap between a successive pair of quiescent states grows too 2384 quiescent state in addition to context switch, idle, user mode, and [all …]
|
| /linux/Documentation/RCU/ |
| A D | stallwarn.rst | 273 The "fqs=" shows the number of force-quiescent-state idle/offline 297 If all CPUs and tasks have passed through quiescent states, but the 306 of jiffies between force-quiescent-state scans, in this case three, 319 through the required quiescent states. The "g" number shows the current
|
| /linux/kernel/rcu/ |
| A D | Kconfig | 85 idle, and user-mode execution as quiescent states. Not for 105 user-mode execution as quiescent states. It forces IPIs and
|
| /linux/tools/memory-model/Documentation/ |
| A D | simple.txt | 126 data sets. For example, each CPU does private quiescent-state processing 128 locking to report quiescent states up the grace-period combining tree.
|
| /linux/Documentation/admin-guide/ |
| A D | kernel-per-CPU-kthreads.rst | 213 CPUs to detect that it has passed through an RCU quiescent 216 the CPU in question has passed through a quiescent state.
|
| /linux/Documentation/virt/kvm/devices/ |
| A D | arm-vgic-its.rst | 205 - The ITS is not enabled and quiescent
|